smart2cfg(1)




NAME

     smart2cfg - Compaq Smart-2 EISA/PCI and Smart-2SL PCI  Array
     Controller ioctl utility


SYNOPSIS

     smart2cfg -c [controller_num]

     smart2cfg -d [controller_num]

     smart2cfg -h

     smart2cfg -l logical_drive_num [controller_num]

     smart2cfg -p physical_drive_num bus_num [controller_num]


DESCRIPTION

     The smart2cfg utility issues controller-specific  ioctls  to
     the  Compaq  Smart-2  EISA/PCI  and Smart-2SL PCI array con-
     troller using the smartii(7D) driver.

     smart2cfg provides information about the Smart-2 and  Smart-
     2SL  controllers  installed  on  the system, the Logical and
     Physical drives as well as  the  details  of  the  ReadWrite
     cache  present on each controller. The utility is text based
     and is driven by command line arguments. smart2cfg  and  the
     smartii(7D)  driver communicate using ioctls. smart2cfg also
     supports multiple commands.


OPTIONS

     The following options are supported:

     -c controller_num
           Prints  cache  details  of  the  cache  on  controller
           controller_num.

     -d controller_num
           Prints details of all the physical disks, all the log-
           ical    drives,    and   the   cache   on   controller
           controller_num.

     -h    Provides on-line help for the smart2cfg utility.

     -l logical_drive_num controller_num
           Prints   logical   drive   details   of   the    drive
           logical_drive_num on controller controller_num.

     -p physical_drive_num bus_num controller_num
           Prints   physical   drive   details   of   the    disk
           physical_drive_num   on   bus  bus_num  on  controller
           controller_num.


EXAMPLES

     Example 1: Providing details of the physical disk

     To provide details of the physical disk with SCSI ID  0,  on
     Bus 0, on controller 0:

     example% smart2cfg -p -0 0 0

     Example 2: Providing logical drive details

     To provide logical drive details of logical drive 0 on  con-
     troller 0:

     example% smart2cfg -l 0 0

     Example 3: Providing cache details

     To provide cache details of controller 0:

     example% smart2cfg -c 0

     Example 4: Providing information of all physical disks, log-
     ical drives, and cache on a controller

     To  provide  information  on  all  physical  disks,  logical
     drives, and cache on controller 0:

     smart2cfg -d

     Example 5: Providing details of the disk

     To provide details of the disk with SCSI ID 0, on Bus 0,  on
     controller  0,  and logical drive details of logical drive 0
     on controller 1:

     example% smart2cfg -p  0  0  0 -l  0  1


FILES

     /devices/eisa/smartii@<instance>,<ioaddr>:ioctlnode

     /devices/pci@0,<bus_num>/pci1014,22@<device_num>/pcie11,4030@0:ioctlnode

     /devices/pci@0,<bus_num>/pci1014,22@<device_num>/pcie11,4031@0:ioctlnode


ATTRIBUTES

     See attributes(5) for descriptions of the  following  attri-
     butes:

     ____________________________________________________________
    |       ATTRIBUTE TYPE        |       ATTRIBUTE VALUE       |
    |_____________________________|_____________________________|
    | Architecture                | x86                         |
    |_____________________________|_____________________________|


SEE ALSO

     attributes(5), smartii(7D)


NOTES

     If the controller is not specified, the first controller  is
     taken as default.


Man(1) output converted with man2html