smart2cfg(1)
NAME
smart2cfg - Compaq Smart-2 EISA/PCI and Smart-2SL PCI Array
Controller ioctl utility
SYNOPSIS
smart2cfg -c [controller_num]
smart2cfg -d [controller_num]
smart2cfg -h
smart2cfg -l logical_drive_num [controller_num]
smart2cfg -p physical_drive_num bus_num [controller_num]
DESCRIPTION
The smart2cfg utility issues controller-specific ioctls to
the Compaq Smart-2 EISA/PCI and Smart-2SL PCI array con-
troller using the smartii(7D) driver.
smart2cfg provides information about the Smart-2 and Smart-
2SL controllers installed on the system, the Logical and
Physical drives as well as the details of the ReadWrite
cache present on each controller. The utility is text based
and is driven by command line arguments. smart2cfg and the
smartii(7D) driver communicate using ioctls. smart2cfg also
supports multiple commands.
OPTIONS
The following options are supported:
-c controller_num
Prints cache details of the cache on controller
controller_num.
-d controller_num
Prints details of all the physical disks, all the log-
ical drives, and the cache on controller
controller_num.
-h Provides on-line help for the smart2cfg utility.
-l logical_drive_num controller_num
Prints logical drive details of the drive
logical_drive_num on controller controller_num.
-p physical_drive_num bus_num controller_num
Prints physical drive details of the disk
physical_drive_num on bus bus_num on controller
controller_num.
EXAMPLES
Example 1: Providing details of the physical disk
To provide details of the physical disk with SCSI ID 0, on
Bus 0, on controller 0:
example% smart2cfg -p -0 0 0
Example 2: Providing logical drive details
To provide logical drive details of logical drive 0 on con-
troller 0:
example% smart2cfg -l 0 0
Example 3: Providing cache details
To provide cache details of controller 0:
example% smart2cfg -c 0
Example 4: Providing information of all physical disks, log-
ical drives, and cache on a controller
To provide information on all physical disks, logical
drives, and cache on controller 0:
smart2cfg -d
Example 5: Providing details of the disk
To provide details of the disk with SCSI ID 0, on Bus 0, on
controller 0, and logical drive details of logical drive 0
on controller 1:
example% smart2cfg -p 0 0 0 -l 0 1
FILES
/devices/eisa/smartii@<instance>,<ioaddr>:ioctlnode
/devices/pci@0,<bus_num>/pci1014,22@<device_num>/pcie11,4030@0:ioctlnode
/devices/pci@0,<bus_num>/pci1014,22@<device_num>/pcie11,4031@0:ioctlnode
ATTRIBUTES
See attributes(5) for descriptions of the following attri-
butes:
____________________________________________________________
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
|_____________________________|_____________________________|
| Architecture | x86 |
|_____________________________|_____________________________|
SEE ALSO
attributes(5), smartii(7D)
NOTES
If the controller is not specified, the first controller is
taken as default.
Man(1) output converted with
man2html