snmpXdmid(1M)
NAME
snmpXdmid - Sun Solstice Enterprise SNMP-DMI mapper subagent
SYNOPSIS
/usr/lib/dmi/snmpXdmid -s hostname [-h] [-c config-dir] [-
d debug-level]
DESCRIPTION
The snmpXdmid utility is a subagent in the Solstice Enter-
prise Agent Desktop Management Interface package. It maps
the SNMP requests forwarded by the Master Agent (
snmpdx(1M)) into one or more equivalent DMI requests.
Further, it remaps the DMI response into SNMP response back
to snmpdx. By default, snmpXdmid also forwards the DMI indi-
cations as SNMP traps to snmpdx. The feature is configur-
able and can be disabled by setting
TRAP_FORWARD_TO_MAGENT=0 in the snmpXdmid configuration
file, snmpXdmid.conf.
This subagent runs as a daemon in the system. The subagent
uses a set of .MAP files located in /var/dmi/map to map the
SNMP Object Identifier (OID) into a corresponding DMI com-
ponent. The map files are generated using the MIF-to-MIB
utility, miftomib. They are read by snmpXdmid when a
corresponding MIF file gets registered with the DMI Service
Provider ( dmispd(1M)).
The snmpXdmid.conf file is used for configuration informa-
tion. Each entry in the file consists of a keyword followed
by an equal sign (=), followed by a parameter string. The
keyword must begin in the first position. A line beginning
with a pound sign (#) is treated as a comment and the subse-
quent characters on that line are ignored. The keywords
currently supported are:
WARNING_TIMESTAMP
Indication subscription expiration, warning time.
EXPIRATION_TIMESTAMP
Indication subscription expiration timestamp.
FAILURE_THRESHOLD
DMISP retries before dropping indication due to comm
errors.
TRAP_FORWARD_TO_MAGENT
0 Drop indication at the subagent level.
non-zero
Forward indications as SNMP traps to snmpdx.
By default, the configuration file snmpXdmid.conf is located
in the /etc/dmi/conf directory. You can specify an alterna-
tive directory with the -c option.
OPTIONS
The following options are supported:
- c config-dir
Specify the directory where snmpXdmid.conf file is
located.
-d debug-level
Debug. Levels from 1 to 5 are supported, giving vari-
ous levels of debug information.
-h Help. Print the command line usage.
-s hostname
Specify the host on which dmispd is running.
FILES
/etc/dmi/conf/snmpXdmid.conf
DMI mapper configuration file
ATTRIBUTES
See attributes(5) for descriptions of the following attri-
butes:
____________________________________________________________
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
|_____________________________|_____________________________|
| Availability | SUNWsadmi |
|_____________________________|_____________________________|
SEE ALSO
dmispd(1M), snmpdx(1M), attributes(5)
Man(1) output converted with
man2html