socal(7D)
NAME
socal - Serial Optical Controller for Fibre Channel Arbi-
trated Loop (SOC+) device driver
SYNOPSIS
socal@sbus-slot,0
DESCRIPTION
The Fibre Channel Host Bus Adapter is an SBus card which
implements two full duplex Fibre Channel interfaces. Each
Fibre Channel interface can connect to a Fibre Channel Arbi-
trated Loop (FC-AL).
The socal device driver is a nexus driver and implements
portions of the FC-2 and FC-4 layers of FC-AL.
FILES
/kernel/drv/socal
ELF Kernel Module
ATTRIBUTES
See attributes(5) for descriptions of the following attri-
butes:
____________________________________________________________
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
|_____________________________|_____________________________|
| Architecture | SPARC |
|_____________________________|_____________________________|
SEE ALSO
sbus(4), sf(7D), ssd(7D)
Writing Device Drivers
ANSI X3.230-1994, Fibre Channel Physical and Signalling
Interface (FC-PH)
ANSI X3.272-1996, Fibre Channel Arbitrated Loop (FC-AL)
Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA)
DIAGNOSTICS
The messages described below may appear on system console
in addition to being logged.
On the console, these messages are preceded by:
socal%d: port %a
where %d is the instance number of the socal controller
and %a is the port on the host adapter.
Fibre Channel Loop is ONLINE
The Fibre Channel loop is now online.
Fibre Channel Loop is OFFLINE
The Fibre Channel loop is now offline.
attach failed: device in slave-only slot.
Move soc+ card to another slot.
attach failed: bad soft state.
Driver did not attach, devices will be inaccessi-
ble.
attach failed: unable to alloc xport struct.
Driver did not attach, devices will be inaccessi-
ble.
attach failed: unable to map eeprom
Driver was unable to map device memory; check for
bad hardware. Driver did not attach to device,
devices will be inaccessible.
attach failed: unable to map XRAM
Driver was unable to map device memory; check for
bad hardware. Driver did not attach to device,
devices will be inaccessible.
attach failed: unable to map registers
Driver was unable to map device registers; check
for bad hardware. Driver did not attach to dev-
ice, devices will be inaccessible.
attach failed: unable to access status register
Driver was unable to map device registers; check
for bad hardware. Driver did not attach to dev-
ice, devices will be inaccessible.
attach failed: unable to install interrupt handler
Driver was not able to add the interrupt routine
to the kernel. Driver did not attach to device,
devices will be inaccessible.
attach failed: unable to access host adapter XRAM
Driver was unable to access device RAM; check for
bad hardware. Driver did not attach to device,
devices will be inaccessible.
attach failed: unable to write host adapter XRAM
Driver was unable to write device RAM; check for
bad hardware. Driver did not attach to device,
devices will be inaccessible.
attach failed: read/write mismatch in XRAM
Driver was unable to verify device RAM; check for
bad hardware. Driver did not attach to device,
devices will be inaccessible.
Man(1) output converted with